Material: Stainless Steel (SS) Housing
Proven rocker-pin Design
Easy Corner Adjustment
Protection Class: IP68 & IP69K
| 5 |
|
0 |
| 4 |
|
0 |
| 3 |
|
0 |
| 2 |
|
0 |
| 1 |
|
0 |
|
|||||||||||||||||||||
| Compression load cell PR 6201 (0.5 t–50 t) | |||||||||||||||||||||
| Parameter | Description | Abbr. | LA | L | D1/N | C3 | C6 | Unit | |||||||||||||
| Accuracy class | 0.25 | 0.25 | 0.04 | 0.015 | 0.008 | %Emax | |||||||||||||||
| Minimum dead load | Lowest limit of specified measuring range | Emin | 0 | %Emax | |||||||||||||||||
| Maximum capacity | Highest limit of specified measuring range | Emax | See Ordering information table | kg | |||||||||||||||||
| Safe load limit | Maximum load without irreversible damage | Elim | For 500 kg … 30 t: 200 For 50 t: 150 | %Emax | |||||||||||||||||
| Destructive load | Danger of mechanical destruction | Ed | For 500 kg … 30 t: >500 For 50 t: >300 | %Emax | |||||||||||||||||
| Minimum LC verification Interval | Minimum verification interval, vmin = Emax/Y For Emax = 1,000 kg For Emax = 500 kg For Emax = 3,000 kg For Emax = 2,000 kg | Y Y Y Y Y | / / / / / | / / / / / | 5,000 3,500 1,750 5,000 5,000 | 14,000 / / 9,000 7,000 | 20,000 / / / / | ||||||||||||||
| Deadload output return | Factor for deadload output return after load (DR=1/2*Emax/Z) For Emax = 50 t | Z Z | / / | / / | 1,000 1,000 | 3,000 3,000 | 8,000 / | ||||||||||||||
| Rated output | Relative output at maximum capacity (LA = 4 … 20 mA) For Emax = 50 t | Cn Cn | 16 mA 16 mA | 1 2 | 1 2 | 1 2 | 1 / | mV/V mV/V | |||||||||||||
| Tolerance on rated output | Permissible deviation from rated output | dc | <1.0 | <1.0 | <0.25 | <0.07 | <0.07 | %Cn | |||||||||||||
| Zero output signal | Load cell output signal under unloaded condition | Smin | 4 mA* | <2.0 | <1.0 | <1.0 | <1.0 | %Cn | |||||||||||||
| Reproducibility | Max. change in load cell output for repeated loading | eR | <0.02 | <0.02 | <0.01 | <0.005 | <0.005 | %Cn | |||||||||||||
| Creep | Max. change of output signal at Emax for 30 min. | dcr | <0.05 | <0.05 | <0.03 | <0.015 | <0.008 | %Cn | |||||||||||||
| Non-linearity | Max. deviation from best straight line through zero | dLin | <0.25 | <0.25 | <0.03 | <0.01 | <0.01 | %Cn | |||||||||||||
| Hysteresis | Max. difference in LC output between loading and unloading | dhy | <0.25 | <0.25 | <0.04 | <0.015 | <0.008 | %Cn | |||||||||||||
| Temperature effect (TK) on Smin | Max. change of Smin in BT | TKSmin | <0.15 | <0.15 | <0.028 | <0.01 | <0.007 | %Cn/10 K | |||||||||||||
| Temperature effect (TK) on parameter | Max. change of C in BT | TKC | <0.1 | <0.1 | <0.03 | <0.01 | <0.005 | %Cn/10 K | |||||||||||||
| Input impedance | Between supply terminals | RLC | / | 650+50 | 650 ±6 | Ω | |||||||||||||||
| Output impedance | Between supply terminals | RO | / | 610 ±3 | 610 ±1 | 610 ±0.5 | Ω | ||||||||||||||
| Insulation impedance | Between measuring circuit and housing at 100 VDC | RIS | / | >5,000 × 106 | Ω | ||||||||||||||||
| Insulation voltage | Between circuit and housing (PR 62../..E only) | / | 500 | V | |||||||||||||||||
| Recommended supply voltage | To hold the specified performance | Bu | 20 … 28 | 4 … 24 | V | ||||||||||||||||
| Max. supply voltage | Permissible for continuous operation without damage | Umax | 28 | 32 (Ex versions: 25) | V | ||||||||||||||||
| Nominal ambient temp. range | To hold the specified performance | BT | -10 … +55 | -10 … +55 | °C | ||||||||||||||||
| Usable temperature range | Permissible for continuous operation without damage | BTu | -30 … +55 | -40 … +95 | °C | ||||||||||||||||
| Storage temperature range | Without electrical and mechanical stress | BTi | -40 … +70 | -40 … +95 | °C | ||||||||||||||||
| Permissible eccentricity | Permissible displacement from nominal load line | Sex | For 500 kg … 10 t: 10 For 20 t … 50 t: 5 | mm | |||||||||||||||||
| Vibration resistance | Resistance against oscillations (IEC 68-2-6 Fc) | 20 g, 100 h, 10 … 150 Hz | |||||||||||||||||||
| Barometric pressure influence | Influence of barometric pressure on output | PKSmin | Up to 2 t: 280 3 t to 10 t: 320 From 20 t: 420 | g/kPa | |||||||||||||||||
| Nominal deflection | Max. elastic deformation under maximum capacity | Snom | Up to 30 t ≤0.5/50 t ≤0.8 | mm | |||||||||||||||||
| Material (load cell housing) | Stainless steel 1.4301 acc. DIN EN 10088-3 (conforms to 304 AISI/SAE) | ||||||||||||||||||||
| Protection class | IP68/IP69 | ||||||||||||||||||||
| Cable | Length: Emax ≤10 t: 5 m, Emax >10 t: 12 m Diameter: 5 mm Cross section: 4 × 0.35 mm2 Material cable sheath: TPE | ||||||||||||||||||||
| Bending radius | ≥25 mm in case of fixed installation ≥75 mm in case of flexible installation | ||||||||||||||||||||
| * Zero output signal tolerance: -2 ± 2%Cn, i.e. 3.36 mA 4.00 mA | |||||||||||||||||||||