No corner adjustment necessary
IP 68 & IP 69K (Wash down cleaning)
Proven rocker-pin principle
100 % Maintenance free
| 5 |
|
0 |
| 4 |
|
0 |
| 3 |
|
0 |
| 2 |
|
0 |
| 1 |
|
0 |
| Technical Data | ||||||||||||
| Maximum capacity | highest limit of specified measuring range | Emax | 12.5 20 | 25 | 30 | 50 | 60 | 75 t | ||||
| Max. usable load | upper limit for measurements | Eu | 37.5 40 | 37.5 | 60 | 75 | 75 | 75 t | ||||
| Destructive load | danger of mechanical destruction | Ed | > 75 > 100 | > 75 | > 150 | > 150 | > 150 | > 150 t | ||||
| Rated output | relative output signal at max. capacity | Cn | 1 1 | 2 | 1 | 2 | 2.4 | 3 mV/V | ||||
| for accuracy classes C4, C5, C6 at Emax > 60 t | 1.5 | 1.5 mV/V | ||||||||||
| C5, C6 at Emax > 50 t | 1.5 | 1.5 | 1.5 mV/V | |||||||||
| Nominal deflection | max.elastic deformation under nominal load | snom | 0.2 0. | 4 | 0.5 | 0.5 | 0.8 | 0.9 | 1.1 mm | |||
| Accuracy class | C3 | C4 | C51) | C61) | ||||||||
| Accuracy class | 0.015 | 0.012 | 0.010 | 0.008 | % Emax | |||||||
| Minimum dead load | lowest limit of specified measuring range | Emin | 0 | 0 | 0 | 0 | % Emax | |||||
| Min.LC verification | minimum load cell verification interval | Y | 14,000 | 20,000 | 20,000 | 20,000 | ||||||
| interval | (vmin = Emax/Y) for Emax 12.5 t: | Y | 14,000 | 18,000 | – | – | ||||||
| Deadload Return | factor for min. dead load output return | Z | 6,000 | 8,0002) | 8,0002) | 8,0002) | ||||||
| (DR = 1/2 Emax/Z) for Emax 12.5 t: | Z | 6,000 | 6,000 | – | – | |||||||
| Tolerance | permissible deviation from rated output | dc | < 0.07 | < 0.07 | < 0.07 | < 0.07 | % Cn | |||||
| on rated output | ||||||||||||
| Zero output signal | load cell output signal under | Smin | < 1.0 | < 1.0 | < 1.0 | < 1.0 | % Cn | |||||
| unloaded condition | ||||||||||||
| Repeatability error | max.change in load cell output | eR | < 0.005 | < 0.005 | < 0.005 | < 0.005 | % Cn | |||||
| for repeated loading | ||||||||||||
| Creep, during 30 min | max.change in load cell output | dcr | < 0.015 | < 0.0125 | < 0.010 | < 0.008 | % Cn | |||||
| under nominal load | ||||||||||||
| Non-linearity | max. deviation from best straight line | dLin | < 0.01 | < 0.01 | < 0.01 | < 0.01 | % Cn | |||||
| through zero | ||||||||||||
| Hysteresis | max. diff.in LC output between loading and | dhy | < 0.0165 | < 0.0125 | < 0.010 | < 0.008 | % Cn | |||||
| unloading | ||||||||||||
| Temperature effect | max. change of Smin/10 K DT over | TKSmin | < 0.01 | < 0.007 | < 0.007 | < 0.007 | %Cn/10 K | |||||
| on Smin | BT referred to Cn | |||||||||||
| Temperature effect | max. change of Cn/10 K DT over | TKc | < 0.01 | < 0.008 | < 0.007 | < 0.005 | %Cn/10 K | |||||
| on Cn | BT referred to Cn | |||||||||||
| Input impedance | between supply terminals | RLC | 1,080 ±10 | 1,080 ±10 | 1,080 ±10 | 1,080 ±10 | O | |||||
| Output impedance | between measuring terminals | RO | 1,010 ± 1 | 1,010 ± 1 | 1,010 ± 1 | 1,010 ± 1 | O | |||||
| for accuracy classes C5 | C6 | at Emax = 50 t | 760 ± 1 | 760 ± 1 | 760 ± 1 | 760 ± 1 | O | ||||||
| C4 | C5 | C6 at Emax = 60 t | 635 ± 1 | 635 ± 1 | 635 ± 1 | 635 ± 1 | O | |||||||
| C4 | C5 | C6 at Emax = 75 t | 510 ± 1 | 510 ± 1 | 510 ± 1 | 510 ± 1 | O | |||||||
| Insulation impedance | between measuring circuit and housing | RIS | > 5,000 | > 5,000 | > 5,000 | > 5,000 | M O | |||||
| at 100 VDC | ||||||||||||
| Insulation voltage | between circuit and housing | 100 | 100 | 100 | 100 | VDC | ||||||
| Ex | 500 | 500 | 500 | 500 | V | |||||||
| Recommended supply to hold the specified performance Bu voltage | 4 … 24 | 4 … 24 | 4 … 24 | 4 … 24 | V | |||||||
| Max. supply voltage permissible for continuous operation Umax | 32 | 32 | 32 | 32 | V | |||||||
| without damage | ||||||||||||
| Ex | 25 | 25 | 25 | 25 | V | |||||||
| Nominal ambient to hold the specified performance BT temp. range | -10 …+55 | -10 …+55 | -10 …+55 | -10 …+55 | °C | |||||||
| Usable ambient permissible for continuous operation BTu temp. range without damage | -40 …+95 | -40 …+95 | -40 …+95 | -40 …+95 | °C | |||||||
| Storage temperature transportation and storage BTl range | -40 …+95 | -40 …+95 | -40 …+95 | -40 …+95 | °C | |||||||
| Permissible eccentricity permissible displacement from nominal Sex | 10 | 10 | 10 | 10 | mm | |||||||
1 in stock